SÍNTESIS Y CARACTERIZACIÓN DE COMPUESTOS HIDROXIAPATITA/TiO 2 PARA APLICACIONES BIOMÉDICAS ( SYNTHESIS AND CHARACTERIZATION OF HYDROXYAPATITE/TiO 2 COMPOSITES FOR BIOMEDICAL APPLICATIONS )
Se prepararon recubrimientos de hidroxiapatita (HA) reforzados con TiO 2 sobre acero AISI 316L mediante el proceso sol gel/dip coating. El espesor de los recubrimientos se determino por microscopia optica confocal, mientras que la fuerza de adherencia se evaluo con un medidor de adhesion pull-off. Despues de seleccionar las mejores condiciones, para la formacion de una pelicula con propiedades mecanicas adecuadas, se evaluo la bioactividad in vitro del recubrimiento durante dos semanas, y se comparo con la de los recubrimientos de HA y TiO 2 . La formacion de apatitas se corroboro con ayuda de la tecnica de SEM EDX. Finalmente, se evaluo la velocidad de corrosion del acero, para estudiar la estabilidad de los recubrimientos. Los resultados mostraron que la formacion de peliculas de HA/TiO 2 llevo a la obtencion de un material bioactivo, con mayor adherencia que la obtenida para las peliculas de HA y el TiO 2 . Sin embargo, la presencia de HA afecto la proteccion contra corrosion promovida por la presencia de TiO 2 . Hydroxyapatite (HA) reinforced with TiO 2 coatings were prepared by sol/gel dip coating on AISI 316L stainless steel. The thickness of the coatings was determined by confocal optical microscopy and the adhesion strength was evaluated by means of a pull-off tester. After selecting the optimal conditions for the formation of a film with good mechanical properties; the in vitro bioactivity of the coating was evaluated for two weeks, and then compared with those of HA and TiO 2 coatings. The growth of apatite was confirmed by SEM EDX characterization. Finally, the corrosion rate of the steel substrate was also evaluated, in order to analyze the stability of the coatings. The results showed that the formation of HA/TiO 2 films produced a bio-active material with a higher adherence, when compared to that obtained for films of HA and TiO 2 . Nevertheless, the presence of HA affected the corrosion resistance of the film, as promoted by the presence of TiO 2 .
Tópico:
Bone Tissue Engineering Materials
Citaciones:
0
Citaciones por año:
No hay datos de citaciones disponibles
Altmétricas:
No hay DOI disponible para mostrar altmétricas
Información de la Fuente:
FuenteRevista Latinoamericana de Metalurgia y Materiales/Revista Latinoamericana de Metalurgía y Materiales