Introduccion: el objetivo de este estudio es identificar los efectos clinicos y microscopicos del uso del laser en el aclaramiento dental sobre dientes humanos vitales. Metodos: en este estudio experimental, la muestra correspondio a 11 pacientes entre 21 y 35 anos, de los cuales se recolectaron 22 dientes premolares sanos, sin restauraciones, fracturas o defectos coronales, con exodoncia indicada por motivos ortodoncicos. Se compararon los efectos de la aplicacion del aclaramiento con GC TiON® (GC dental, Washington, USA), con LED/Laser Ultrablue IV y sin el (DMC Equipamentos Sao Paulo, Brasil). Los dientes se dividieron en tres grupos: grupo control (n = 2), grupo 1 (n = 10) se aplico el GC TiON® y laser y grupo 2 (n = 10) se aplico el GC TiON ® sin laser. Posterior al aclaramiento, los dientes se extrajeron y se conservaron en agua destilada. Se hizo toma de color antes y despues de cada sesion de aclaramiento. Las alteraciones en la superficie vestibular de las muestras fueron analizadas con microscopia lectronica de barrido. Resultados: el 85% (17 casos) no mostraron ninguna alteracion en el esmalte, el 10% (2 casos) presento alteraciones leves y solo el 5% (1 caso) tuvo alteracion moderada en esmalte. No existio gran diferencia en el cambio de color entre los grupos; de las 20 muestras, 6 llegaron al tono B1 en la primera sesion, 7 en la segunda sesion y 7 en la tercera sesion. Conclusiones: con la microscopia electronica no se evidenciaron danos severos en la estructura dental. No se presento diferencia significativa en el grado de aclaramiento dental. ABSTRACT. Introduction: the objective of this study was to identify the clinical and morphological laser effects on human vital teeth during dental bleaching procedures. Methods: this experimental study included 11 patients ages 21 to 35, from whom 22 healthy premolar teeth, with no restorations, fractures or crown defects were collected. These premolar teeth were extracted because of orthodontic reasons. The effects of performing dental bleaching with GC TiON® (GC dental, Washington, USA), and with and without LED/Laser Ultrablue IV (DMC Equipments Sao Paulo, Brasil) were compared. The teeth were divided into three groups: control group (n = 2), group 1 (n = 10), using GC TiON® with laser, and group 2 (n = 10), using GC TiON® without laser. After extraction, the teeth were conserved in distilled water. Color monitoring was performed before and after each whitening session. Alterations on the buccal surface of the samples were analyzed by means of Scanning Electron Microscopy (SEM). Results: 85% of the teeth (17) did not show enamel alterations, 10% (2 teeth) presented mild alterations, and only 5% (1 tooth) suffered moderate enamel alterations. No significant color change difference occurred among the groups; out of the 20 samples, 6 of them reached tone B1 in the first session, 7 in the second session, and 7 more in the third one. Conclusions: Scanning Electron Microscopy did not reveal severe damage in dental structure. No significant difference in teeth whitening level occurred.
Tópico:
Laser Applications in Dentistry and Medicine
Citaciones:
2
Citaciones por año:
Altmétricas:
No hay DOI disponible para mostrar altmétricas
Información de la Fuente:
FuenteRevista Facultad de Odontología Universidad de Antioquia