While linear control techniques for dynamic systems have been widely tested, systems are not linear in practice. This means that controllers must be re-tuned to make them useful in an experimental setup. This article presents the tuning and re-tuning process for two control strategies: a PID and an algorithm based on the choice of overall transfer function controlling a DC permanent magnet motor. The algorithms’ performance is evaluated and some recommendations are made.