A flexible intravenous microdialysis probe was constructed from Silastic tubing (0.5 mm ID and 1.0 mm OD), with a cellulose hollow fiber tip 0.2 mm in diameter and 25 mm long with a 6,000 mol wt cut off. In vitro tests showed relative recovery rates of 39.1 +/- 1.9% for epinephrine. In vivo tests in freely moving rats, 36 h and 7 days after surgery, showed stable amounts of epinephrine and glucose. After intraperitoneal injections of 2-deoxy-D-glucose, circulating levels of epinephrine and glucose increased significantly. Similar results were obtained several days after implantation of the probe. We conclude that in situations where prolonged blood sampling is necessary, the flexible microdialysis probe provides a reliable means of accessing circulating levels of neuroactive compounds, nutrients, metabolites, and drugs.