Logotipo ImpactU
Autor

Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons

Acceso Abierto
ID Minciencias: ART-0000140139-3190
Ranking: ART-ART_A2

Abstract:

The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3 % in the barrel and 2.8 % in the endcaps. This leads to an estimated contribution to the constant term of (0.29 +0.05 -0.04) % in the barrel and (0.54 +0.06 -0.04) % in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61 +- 0.07 mm/\mu s at 88.5 K and 1 kV/mm.

Tópico:

Particle Detector Development and Performance

Citaciones:

Citations: 63
63

Citaciones por año:

Altmétricas:

Paperbuzz Score: 0
0

Información de la Fuente:

SCImago Journal & Country Rank
FuenteThe European Physical Journal C
Cuartil año de publicaciónNo disponible
Volumen70
Issue3
Páginas755 - 785
pISSN1434-6044
ISSNNo disponible

Enlaces e Identificadores:

Artículo de revista