A system is described which extends reflection coefficient measurement techniques to E-band (60 to 90 GHz). Special apparatus and procedures are discussed. A new graphical presentation of reflectometer data is given which simplifies the measurement of counector impedance. Examples of the measured reflection coefficient magnitudes of some common E-band connectors are given.